Potential Production

Picture











Estimated Micro Hydro Electricity Production

-Assumptions-

Wet Season Flow Rate: 200 l/sec

Dry Season Flow Rate: 80 l/sec

Elevation Change: 150 m

System Efficiency of 50%

U=mgh

=80l/sec*9.8m/s/s*150m

=117,600 Watts

117,600*50% eff = 58.8 kw


Source: Steve Crowe, Alterna and author’s own computations