Potential Production
Estimated Micro Hydro Electricity Production
-Assumptions-
Wet Season Flow Rate: 200 l/sec
Dry Season Flow Rate: 80 l/sec
Elevation Change: 150 m
System Efficiency of 50%
U=mgh
=80l/sec*9.8m/s/s*150m
=117,600 Watts
117,600*50% eff = 58.8 kw
Source: Steve Crowe, Alterna and author’s own computations